Licensing Tips Part 3: Auto-LogOut Feature

UniCam Security now supports an Auto-Logout feature for both UniCam FX v9.2+ and Test Expert v9.3+. By default, the auto-logout is set to enabled, with a value of 10 minutes. This is a User level setting found in the Properties dialog for each user when in the “Security and Licensing” tool.

Auto-LogOut Feature

If you want to disable all users (or enable all users), you can use the “Secset.exe” utility found in folder where the security software is installed on the license server, (by default “C:\Unicam Security”).  To do this:

1. Open an Administrative Command Prompt on the license server.

2. Navigate to your Unicam Security” folder. CD C:\Unicam Security

3. The possible command lines for the utility are:

SECSET AUTOLOGOUT ON : Enable autologout for all users

SECSET AUTOLOGOUT OFF : Disable autologout for all users

You can also now use this command line:

SECSET AUTOLOGOUT ON 60 : This will enable auto-logout for all users, and set to 60 minutes (or whatever you specify).

If Security & Licensing Admin tool is open when you run the SECSET utility, you will need to close and re-open the Security Admin tool to see the changes.

Have more licensing questions? Be sure to read Part 1 (Installing a New License) and Part 2 (Replacing a License File).